Direkt zum Inhalt
Startseite
  • English
  • Deutsch
  • Français
  • Italiano
  • Polski
  • Andere Sprachen

User account menu

  • Anmelden

User login

  • Neues Benutzerkonto erstellen
  • Passwort zurücksetzen

Main navigation

  • Unternehmen
    • Über uns
    • Geschäftsführung
    • Karriere bei Radium
    • Geschichte
    • Qualität/Umwelt
    • Compliance
    • Partner/Verbände
  • Produktkatalog
    • LED-Lampen
    • Betriebsgeräte, LED Treiber
    • LED-Strips und Zubehör
    • Smart Lighting - Komponenten für die Lichtsteuerung
    • Entladungslampen
    • Leuchtstofflampen
    • Halogen- und Glühlampen
    • Export/ Non-EU
    • Signallampen
    • Spezialstrahler UV
    • Spezialstrahler sichtbares Licht
    • Spezialstrahler IR
  • Produktgruppen
    • NEU! LED-Leuchten
    • LED Strips
    • Easy Connect LED Strips
    • LED Neo Röhren
    • LED Lampen
    • Traditionelle Lampen
    • Halogen-Metalldampflampen
    • SMART Lighting
    • XERADEX®
    • Infrarot-Strahler
    • Radium Vorerzeugnisse
  • Service & Tools
    • LED Strip Konfigurator
    • LED‘s Save
    • Downloads
    • Katalogbestellung
    • Referenzen
    • Konfektionierungsdienstleistungen
    • Garantie LED
    • Gewährleistung und Garantie
    • Webinare
  • News & Wissen
    • News
    • Anwendung LED Tubes
    • EU Richtlinien für Licht und Lampen
    • Entsorgung Altlampen und Bruch
    • Konformität beim Dimmen
    • Hintergrundwissen
    • Lampentausch
    • Energie sparen!
  • Kontakt & Händler
    • Kontaktieren Sie uns
    • Händlersuche
    • Vertretungen
High pressure sodium lamp , RNP-T 400W/230/E40 EX

Artikelnummer: 34422204

High pressure sodium lamp , RNP-T 400W/230/E40 EX

Mobile Menu

  • Unternehmen
  • Produktkatalog
  • Produktgruppen
  • Service & Tools
  • News & Wissen
  • Kontakt & Händler

Pfadnavigation

  1. Product Catalogue
  2. Export/ Non-EU
  3. RNP High Pressure Sodium Vapour Lamps/ Non-EU
  4. High pressure sodium lamp , RNP-T 400W/230/E40 EX
Standard high pressure sodium lamp, tubular bulb clear, base E40, for sales outside EU, without CE-marking.
  • Auf die Vergleichsliste
  • PDF Version
  • 400.0 W
  • 400 W
  • 48000 lm
  • 2000 K
  • 20000 h
  • Tube, single-ended
  • Inaktiv

Bildergalerie

Produktbild - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Produktbild - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Zeichnung - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Energielabel - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Picto Picto Picto

General Data

34422204
RNP-T 400W/230/E40 EX
4008597222047
12
4008597422041
2.86
0.27
0.22
0.36
173 g
Inaktiv

Electric Parameters

392.0 W
400 W
105 V
230 V
4.0 up to 5.0
4.6 A
4.6 A
45 µF
125%
Daelay-action; min. double nominal current
up to 50% (Run up at nominal power)

Light Application Parameters

48000 lm
48000 lm
120 lm/W
111 lm/W
2000 K
25
0.97
0.96
0.95
0.94
0.92
0.91
0.89

Service Life

20000 h
8000 h
11000 h
0.99
0.98
0.95
0.90
0.87
0.74
0.50

Specification

old label, no EPREL registration, no EU data sheet
A+
47 mm
285 mm
285 mm
h180
19.9 mg
Tube, single-ended
Clear
E40

Notes on Operation

h180

Information especially for EPREL

old label, no EPREL registration, no EU data sheet

Miscellaneous

13.04.2012
TIM

Hinweis

Sockelübersicht

Sockel-ZeichnungE40
IEC/EN 60061-1
sheet 7004-24-6

Spektrale Strahlungsverteilung

Spektrum 1RNP Standard/Super

Spektrum 2daylight(D 65)

Schaltbeispiel(e)

Schaltbild1Standard circuit HID with external ignitor
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

The required control gear (here ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild3ECG-operation with additional ignitor
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential
Z = ignitor

The required control gear (here ignitor and electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Besonderheiten

Picto Picto Picto

Allgemeine Hinweise

The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages.
® = Registered trademark
Subject to change without notice. Errors and omissions excepted.


Passende Produkte

Ähnliche Produkte

Produktvergleich

Vergleichen Sie Produkte oder sehen Sie sich Produkte an, die Sie auf die Vergleichsliste gesetzt haben.

Mehr

Product News

Radium LED Leuchten

Radium LED-Leuchten für professionelle Anwendungen.

13.10.2025 - Unser Produktsortiment wächst.

Entdecken Sie schon bald unsere Auswahl an hochwertigen LED-Leuchten. Unter…

Easy Connect LED Strips

Radium Easy Connect LED Strips.

09.10.2025 - Easy, smart, flexibel.

Mit den Radium Easy Connect LED Strips setzen Sie Ihre Lichtideen ganz unkompliziert um. Die…

Weiterlesen
LED‘s Save

 LED´s Save

Austauschen und Sparen mit Radium LED-Lampen

Finden Sie die richtige LED Austausch-Lampe und lassen die Einsparung berechnen.

Jetzt berechnen

Energieverbrauch/ Kosten

Stromverbrauch kWh pro Jahr:
Stromkosten pro Jahr:
Lampenkosten pro Jahr:
Gesamtkosten pro Jahr:
34422204
€

Weitere Basis-Daten:

Nutzungs-Szenario:
Haushalt
Mit LED vergleiche

 Katalogbestellung

Broschüren und Kataloge...
...als Download oder im Druck: Erhalten Sie hier die "Hardware" für Ihre tägliche Arbeit!

 

katalog

Bestellen Downloaden

Händlersuche

Suchen Sie Händler in Ihrer Umgebung

Feedback

Footer

  • © Radium 2025
  • Nutzungsbedingungen
  • AGB
  • Cookie Policy
  • Datenschutz
  • Einkaufsbedingungen
  • Exportkontrollklausel
  • Impressum
  • Kontaktieren Sie uns