High pressure sodium lamp , RNP-T 400W/230/E40 EX

Article No.: 34422204

High pressure sodium lamp , RNP-T 400W/230/E40 EX

Mobile Menu

  • katalog produktów
  • grupy produktów
  • Kontakt i dealer

Ścieżka nawigacyjna

  1. katalog produktów
  2. Export/ Non-EU
  3. RNP High Pressure Sodium Vapour Lamps/ Non-EU
  4. High pressure sodium lamp , RNP-T 400W/230/E40 EX
Standard high pressure sodium lamp, tubular bulb clear, base E40, for sales outside EU, without CE-marking.
  • Add to compare
  • PDF version
  • 400.0 W
  • 400 W
  • 48000 lm
  • 2000 K
  • 20000 h
  • Tube, single-ended
  • Nieaktywne

Image Gallery

Produktbild - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Produktbild - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Zeichnung - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Energielabel - High pressure sodium lamp , RNP-T 400W/230/E40 EX
Picto Picto Picto

General Data

34422204
RNP-T 400W/230/E40 EX
4008597222047
12
4008597422041
2.86
0.27
0.22
0.36
173 g
Nieaktywne

Electric Parameters

392.0 W
400 W
105 V
230 V
4.0 up to 5.0
4.6 A
4.6 A
45 µF
125%
Daelay-action; min. double nominal current
up to 50% (Run up at nominal power)

Light Application Parameters

48000 lm
48000 lm
120 lm/W
111 lm/W
2000 K
25
0.97
0.96
0.95
0.94
0.92
0.91
0.89

Service Life

20000 h
8000 h
11000 h
0.99
0.98
0.95
0.90
0.87
0.74
0.50

Specification

old label, no EPREL registration, no EU data sheet
A+
47 mm
285 mm
285 mm
h180
19.9 mg
Tube, single-ended
Clear
E40

Notes on Operation

h180

Information especially for EPREL

old label, no EPREL registration, no EU data sheet

Miscellaneous

13.04.2012
TIM

Notatki

Base

Sockel-ZeichnungE40
IEC/EN 60061-1
sheet 7004-24-6

Spectrum

Spektrum 1RNP Standard/Super

Spektrum 2daylight(D 65)

Circuit diagram(s)

Schaltbild1Standard circuit HID with external ignitor
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

The required control gear (here ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild3ECG-operation with additional ignitor
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential
Z = ignitor

The required control gear (here ignitor and electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Special features

Picto Picto Picto

General notes

The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages.
® = Registered trademark
Subject to change without notice. Errors and omissions excepted.


Matching Products

Similar Products

Compare products

Compare products or see the products that have been saved to comparison.

Więcej

Product News

LED‘s Save

 LED´s Save

Save with Radium LED lamps replacement

Find the right LED exchange lamp and have the savings calculated.

Calculate now

Energy consumption / costs

Electricity kWh per year:
Electricity costs per year:
Lamp costs per year:
Total cost per year:
34422204
€

Additional basic data:

Usage Scenario:
Household
Compare with LED

Find a dealer

Search dealers in your area

Prześlij opinię

Footer

  • © Radium 2025
  • Warunki korzystania
  • Warunki i postanowienia
  • klauzula kontroli eksportu
  • ochrona danych
  • odcisk