Skip to main content
Home
  • English
  • Deutsch
  • Français
  • Italiano
  • Polski
  • Other languages

User account menu

  • Log in

User login

  • Create new account
  • Reset your password

Main navigation

  • Business
    • About us
    • Management
    • History
    • Quality/Environment
    • Compliance
    • Partner
  • Product Catalogue
    • LED Lamps
    • Control Gear, LED Drivers
    • LED Strips
    • Smart Lighting - Lighting Control Components
    • LED Luminaires
    • Discharge lamps
    • Fluorescent lamps
    • Halogen and Incandescent Lamps
    • Export/ Non-EU
    • Signal Lamps
    • UV
    • Special Lamps visible light
    • IR
  • Product Groups
    • NEW! LED Luminaires
    • LED Strips
    • Easy Connect LED Strips
    • LED Neo Tubes
    • LED Lamps
    • Traditional Lamps
    • Metal Halide Lamps
    • UV Lamps by Radium TECH
    • Infrared Lamps from Radium TECH
    • Radium Primary Material
  • Service & Tools
    • LED Strip Configurator
    • LED‘s Save
    • Downloads
    • Catalogue Order
    • References
    • Individual Cut
    • LED Guarantee
    • Webinars (in German)
    • Webinar Recordings
  • News & Background
    • News
    • Application of LED Tubes
    • EU Guidelines for light and luminaires
    • Disposal of waste lamps and fracture
    • Dimming Conformity
    • Background Knowledge
    • Relamping
    • Save Energy!
  • Contact & Dealer
    • Contact us
    • Representations
Metal halide lamp with quartz burner , HRI-TS 1000W/D/S/ECG/K12S

Article No.: 32416647

Metal halide lamp with quartz burner , HRI-TS 1000W/D/S/ECG/K12S

Mobile Menu

  • Business
  • Product Catalogue
  • Product Groups
  • Service & Tools
  • News & Background
  • Contact & Dealer

Breadcrumb

  1. Product Catalogue
  2. Discharge lamps
  3. Metal Halide Lamps with Quartz Burner
  4. Metal halide lamp with quartz burner , HRI-TS 1000W/D/S/ECG/K12S
Metal halide short arc lamp clear, daylight, high luminous flux, base K12s. Operation in enclosed luminaire and with ECG (no flicker).
  • Add to compare
  • PDF download
  • Calculate consumption data
  •  
  • 1,200.0 W
  • 117000 lm
  • 6000 K
  • 6000 h
  • Tube, double-ended
  • Inactive

Image Gallery

Produktbild - Metal halide lamp with quartz burner , HRI-TS 1000W/D/S/ECG/K12S
Produktbild - Metal halide lamp with quartz burner , HRI-TS 1000W/D/S/ECG/K12S
Zeichnung - Metal halide lamp with quartz burner , HRI-TS 1000W/D/S/ECG/K12S
Energielabel - Metal halide lamp with quartz burner , HRI-TS 1000W/D/S/ECG/K12S
Picto Picto

General Data

32416647
HRI-TS 1000W/D/S/ECG/K12S
4008597166471
10
4008597466472
1.411
0.4
0.17
0.27
59 g
Inactive

Electric Parameters

1200.0 W
125-150 V
230 V
9.6 A
No

Light Application Parameters

117000 lm
117000 lm
97.5 lm/W
97 lm/W
daylight
6000 K
88
0.98
0.98
0.97
0.88
0.81
0.79
0.76

Service Life

6000 h
2500 h
0.97
0.79
0.50

Specification

no Label needed (> 82.000 lm)
A+
41 mm
187 mm
187 mm
p15/s15
75.0 mg
Tube, double-ended
Clear
K12s-36
White

Notes on Operation

p15/s15

Information especially for EPREL

no Label needed (> 82.000 lm)

Miscellaneous

TIM
32416576, 32416593

Notes

Base

Sockel-ZeichnungK12s-36
IEC/EN 60061-1
Sheet 7004-168-1

Spectrum

Natural daylight is a mixture of direct sunlight and the light of the sky. Therefore, its spectral composition changes permanently due to the changing time of day. The standardised light classification D65 corresponds to a daylight with a colour temperature of approximately 6500 K.
Every discharge lamp type has got an individual spectral power distribution according to its chemical filling. From this result important properties light colour or colour rendering.
Should the spectral lines be very close together the lamp presumably has got a very good colour rendering index, so, Ra might be near 100. Does the spectrum rather look like single lines or frayed out the colour rendering of the lamp will probably be not as good.
If number and height of the spectral lines within the blue range (around 400 nm) prevails it might be a lamp with a rather cold light colour like for example daylight. On the other hand, should the red (around 700 nm) or the red and yellow (around 600 nm) range be dominant one can assume that the lamp will be a rather warm light colour like WDL.
After the lamp start a metal hlide lamp needs about 2-4 minutes time to reach its full luminous flux, all colours in the spectrum are within the discharge arc then.
Visible region from 380 to 780 nm; height of graph corresponding with relative spectral emission (400mW/klm) per 10nm.

Spektrum 1HRI.../D

Spektrum 2daylight(D 65)

Circuit diagram(s)

Schaltbild1EVG-Betrieb
Zeichenerklärung:
L. = Lampe
EVG = Elektronisches Vorschaltgerät
P = Phase
N = Null-Leiter

Die notwendigen Geräte (hier elektronisches Vorschaltgerät) zum Betrieb der Lampe sind normalerweise bereits in den dafür geeigneten Leuchten in der entsprechenden Schaltung installiert. Änderungen aller Art sind nur von qualifiziertem Fachpersonal durchzuführen. Dieses Schaltungsbeispiel ist daher lediglich als technische Hintergrund-Information für interessierte Anwender zu verstehen.

Special features

Picto Picto

General notes

The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages.
® = Registered trademark
Subject to change without notice. Errors and omissions excepted.


Downloads

Declaration of Conformity
User Instruction

Matching Products

Similar Products

Compare products

Compare products or see the products that have been saved to comparison.

More

Product News

Newsletter

New Products Newsletter: Everything at a Glance.

26.03.2026 - Up-to-date information on products and their technical specifications.

Stay up to date with our New Products Newsletter. It provides you with regular updates on our…

Highbay Star

LED Highbay Star – Versatile Applications for Industry & Commerce.

25.03.2026 - Customizable, energy-efficient high-bay lighting.

Our new LED Highbay Star is the ideal solution for demanding lighting applications in industry…

Read more

 Catalogue Order

Brochures and Catalogues...
...as download or in print:
Get the 'hardware' for your daily work here!

 

katalog

Order Download

Find a dealer

Search dealers in your area

Feedback

Footer

  • © Radium 2026
  • Terms of Use
  • Delivery and Payment Terms
  • Contact Us
  • Cookie Policy
  • Data Protection
  • Export Control Clause
  • Imprint
  • Purchasing Conditions