Salta al contenuto principale
Home
  • English
  • Deutsch
  • Français
  • Italiano
  • Polski
  • Other languages

User account menu

  • Accedi

User login

CAPTCHA
Questa domanda è un test per verificare che tu sia un visitatore umano e per impedire inserimenti di spam automatici.
  • Crea nuovo profilo
  • Reimposta la tua password

Main navigation

  • Product Catalogue
    • LED Lamps
    • Control Gear, LED Drivers
    • LED Strips
    • Smart Lighting - Lighting Control Components
    • LED Luminaires
    • Discharge lamps
    • Fluorescent lamps
    • Halogen and Incandescent Lamps
    • Export/ Non-EU
    • Signal Lamps
    • UV
    • Special Lamps visible light
    • IR
  • Gruppi di prodotti
    • XERADEX®
    • Emettitore a infrarossi
High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S

Article No.: 34411782

High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S

Mobile Menu

  • Product Catalogue
  • Gruppi di prodotti

Briciole di pane

  1. Product Catalogue
  2. Discharge lamps
  3. RNP High Pressure Sodium Vapour Lamps
  4. High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S
Compact high pressure sodium lamp, tubular bulb clear, base RX7s. Operation with ballast and ignitor.
  • Add to compare
  • PDF version
  • Calculate consumption data
  •  
  • 70.0 W
  • 70 W
  • 6600 lm
  • 2000 K
  • 28000 h
  • Tube, double-ended
  • Inattivo

Image Gallery

Produktbild - High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S
Produktbild - High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S
Zeichnung - High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S
Energielabel - High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S
Energielabel - High pressure sodium lamp , RNP-TS/LR 70W/S/230/RX7S
Picto

General Data

34411782
RNP-TS/LR 70W/S/230/RX7S
4008597117824
12
4008597417825
0.453
0.176
0.136
0.155
21 g
Inattivo

Electric Parameters

70.0 W
70 W
77 kWh
90 V
230 V
4.0 up to 5.0
25 kV
0.98 A
1 A
12 µF
125%
Daelay-action; min. double nominal current
up to 50% (Run up at nominal power)

Light Application Parameters

6600 lm
6600 lm
94.29 lm/W
94 lm/W
2000 K
25
0.94
0.90
0.88
0.86
0.83
0.81
0.80

Service Life

28000 h
0.99
0.98
0.98
0.95
0.80
0.50

Specification

old label, no EPREL registration, no EU data sheet
F
A+
20 mm
120 mm
120 mm
114.2 mm
p45
18.0 mg
Tube, double-ended
Clear
RX7S

Notes on Operation

p45

Information especially for EPREL

old label, no EPREL registration, no EU data sheet
869018

Miscellaneous

TIM
32420042, 32419665

Note

Base

Sockel-ZeichnungRX7s
IEC/EN 60061-1
sheet 7004-92A-4

Spectrum

Natural daylight is a mixture of direct sunlight and the light of the sky. Therefore, its spectral composition changes permanently due to the changing time of day. The standardised light classification D65 corresponds to a daylight with a colour temperature of approximately 6500 K.
Every discharge lamp type has got an individual spectral power distribution according to its chemical filling. From this result important properties light colour or colour rendering. Sodium vapour lamps are very economic, due to the yellow light RNP lamps have got a high luminous efficiency but only modest colour rendering.
After the lamp start a high pressure sodium lamp needs about 6-10 minutes time to reach its full luminous flux.
Visible region from 380 to 780 nm; height of graph corresponding with relative spectral emission (400mW/klm)per 10nm.

Spektrum 1RNP Standard/Super

Spektrum 2daylight(D 65)

Circuit diagram(s)

Schaltbild1Standard circuit HID with external ignitor
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

The required control gear (here ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2ECG-operation
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild3Circuit for 230V-HID-lamps suitable for hot restrike
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

The required control gear (here ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild4ECG-operation with additional ignitor
Key:
L. = lamp
EVG = electronic ballast
P = phase
N = zero potential
Z = ignitor

The required control gear (here ignitor and electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Special features

Picto

General notes

The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages.
® = Registered trademark
Subject to change without notice. Errors and omissions excepted.


Technical Information

Declaration of Conformity
User Instruction

Matching Products

Similar Products

Compare products

Compare products or see the products that have been saved to comparison.

Altro

Product News

Find a dealer

Search dealers in your area

Feedback

Footer

  • © Radium 2026
  • Termini di utilizzo
  • Termini e Condizioni
  • Clausola di controllo delle esportazioni
  • Condizioni di acquisto
  • Protezione dei dati
  • impronta