Fluorescent lamp Skylux , NL-T8 36W/880/G13

Article No.: 31114123

Fluorescent lamp Skylux , NL-T8 36W/880/G13

Mobile Menu

  • Product Catalogue
  • Gruppi di prodotti

Briciole di pane

  1. Product Catalogue
  2. Fluorescent lamps
  3. Fluorescent Lamps T8
  4. Fluorescent lamp Skylux , NL-T8 36W/880/G13
Fluorescent lamp T8 - 26mm diameter, light colour 880, high luminous efficiency, good colour rendering, long life, base G13. Controllable by Dim-ECG.
  • Add to compare
  • PDF version
  • Calculate consumption data
  •  
  • 36.0 W
  • 36 W
  • 3000 lm
  • 8000 K
  • 20000 h
  • Rod
  • Inattivo

Image Gallery

Produktbild - Fluorescent lamp Skylux , NL-T8 36W/880/G13
Produktbild - Fluorescent lamp Skylux , NL-T8 36W/880/G13
Zeichnung - Fluorescent lamp Skylux , NL-T8 36W/880/G13
Zeichnung - Fluorescent lamp Skylux , NL-T8 36W/880/G13
Energielabel - Fluorescent lamp Skylux , NL-T8 36W/880/G13
Energielabel - Fluorescent lamp Skylux , NL-T8 36W/880/G13
Picto

General Data

31114123
NL-T8 36W/880/G13
4008597141232
25
4008597441233
5.11
1.241
0.148
0.145
163 g
Inattivo

Electric Parameters

36.0 W
36 W
43 kWh
103 V
230 V
430 mA
4.5 µF
Sì

Light Application Parameters

3010 lm
3000 lm
25 °C
83.33 lm/W
84 lm/W
Skylux
8000 K
80-89
1.2
0.96
0.94
0.93
0.91
0.91
0.90
0.89

Service Life

20000 h
0.99
0.99
0.99
0.99
0.99
0.90
0.50

Specification

old label, no EPREL registration, no EU data sheet
A
26 mm
26 mm
1200 mm
1200 mm
2.5 mg
Rod
G13
Other

Information especially for EPREL

old label, no EPREL registration, no EU data sheet
1426579

Miscellaneous

01.09.2023
SLR = (EU) 2019/2020
31120339

Note

Base

Sockel-ZeichnungG13
IEC/EN 60061-1
sheet 7004-51-8

Spectrum

Da das Tageslicht eine Mischung von direktem Sonnenlicht und Himmelslicht darstellt, wechselt seine spektrale Zusammensetzung bedingt durch Tageszeit und Wetter ständig. Die Normlichtart D65 entspricht einem Tageslicht mit einer Farbtemperatur von ungefähr 6500 K. Das ist die Zeit, in der wir Menschen aktiv sind. Nach der circadianen Rhythmik bestimmt im Wesentlichen die Lichtmenge und das Spektrum des Lichtes über Hormone die menschliche Leistungsfähigkeit.
Die Lichtfarbe 880 Skylux bringt mit ihrem hohen blauen Farbanteil und Farbtemperatur 8000 K Lichtenergie für Aktivität und Leistung. Sie ist bestens für hohe Sehanforderungen geeignet, fördert Konzentration und unterstützt physische und psychische Leistungsfähigkeit. Die Farbwiedergabe-Eigenschaften sind vergleichbar anderen Dreibanden-Leuchtstofflampen, Ra 80-89.
Sichtbarer Bereich von 380 bis 780 nm; Bildhöhe entspricht der relativen spektralen Emission (400mW/klm)pro 10nm.

Spektrum 1Lichtfarbe Skylux 880

Spektrum 2daylight(D 65)

Circuit diagram(s)

Schaltbild1One-lampe ciruit inductive
Key:
D = choke
L. = lamp
St = starter
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor

The required control gear (here starter and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2One-lampe ciruit with electronic ballast
Key:
VG = ballast electronic (ECG)
P = phase
N = zero potential
Ctrl = Controller, dimmer

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2One-lampe ciruit with electronic ballast
Key:
VG = ballast electronic (ECG)
P = phase
N = zero potential
Ctrl = Controller, dimmer

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2One-lampe ciruit with electronic ballast
Key:
VG = ballast electronic (ECG)
P = phase
N = zero potential
Ctrl = Controller, dimmer

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild3Three phase current connection
Key:
D = choke
L. = lamp
St = starter
VG = ballast electromagnetic (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor

The required control gear (here starter and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Special features

Picto

General notes

The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages.
® = Registered trademark
Subject to change without notice. Errors and omissions excepted.


Technical Information

Energylabel acc. to 2019/2015, A to G
Energylabel acc. to 874/2012, A++ to E
Declaration of Conformity

Matching Products

Similar Products

Power Consumption

Power
36.0 W
Mean service life
20000 h
Number of lamps (pcs)
Number of burning hours (h)
Electricity Price (€ / kWh)
Power Consumption
Electricity costs
Transfer to LED‘s Save
Calculate now

Cable Length

Number of lamps (pcs)
Cable cross-section
Voltage drop
Max. cable length
Calculate now

Cable Length

Number of lamps (pcs)
Cable cross-section
Voltage drop
Max. cable length
Calculate now

Compare products

Compare products or see the products that have been saved to comparison.

Altro

LED‘s Save

 LED´s Save

Save with Radium LED lamps replacement

Find the right LED exchange lamp and have the savings calculated.

Calculate now

Energy consumption / costs

Electricity kWh per year:
Electricity costs per year:
Lamp costs per year:
Total cost per year:
31114123
€

Additional basic data:

Usage Scenario:
Household
Compare with LED

Product News