Aller au contenu principal
Accueil
  • English
  • Deutsch
  • Français
  • Italiano
  • Polski
  • Autres langues

User account menu

  • Se connecter

User login

CAPTCHA
Cette question sert à vérifier si vous êtes un visiteur humain ou non afin d'éviter les soumissions de pourriel (spam) automatisées.
  • Créer un nouveau compte
  • Réinitialiser votre mot de passe

Main navigation

  • Société
    • A propos de nous
    • Direction
    • Histoire
    • Qualité / Environnement
    • Conformité
  • Catalogue des Produits
    • Lampes LED
    • Matériels, Appareillage LED
    • LED Strip - Modules LED et accessoires
    • Smart Lighting - composants pour gestion d'éclairage
    • Luminaires LED
    • Lampes à décharge
    • Lampes fluorescentes
    • Lampes halogènes et à incandescence
    • Exportation NON-CE
    • Lampes de signalisation
    • UV
    • Lampes spéciales lumière visible
    • IR
  • Groupes de produits
    • NOUVEAU! Luminaires LED
    • Bandes LED, LED Strips
    • Strips LED Easy Connect
    • LED Neo Tubes
    • Lampes LED
    • Lampes traditionnelles
    • Lampes UV de Radium TECH
    • Lampes Infrarouge de Radium TECH
    • Précurseurs du Radium
  • Service & Outils
    • LED Strip Configurateur
    • LED‘s Save
    • Téléchargements
    • Commande catalogue
    • Références (en allemand)
    • Emballage
    • Garantie LED
    • Webinaires (en allemand)
  • Nouvelles & Savoir
    • Nouvelles
    • Utilisation LED Tubes
    • Directives européennes pour lumière et lampes
    • Traitement des déchets des lampes usées et cassées
    • Conformité en faire varier l'intensité de lumière
    • Savoir contextuel
    • Echange des lampes
    • Économiser Énergie!
  • Contact & distributeurs
    • Contact
    • Représentations
Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13

Code Radium: 31518151

Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13

Mobile Menu

  • Société
  • Catalogue des Produits
  • Groupes de produits
  • Service & Outils
  • Nouvelles & Savoir
  • Contact & distributeurs

Fil d'Ariane

  1. Product Catalogue
  2. Fluorescent lamps
  3. Fluorescent Lamps T8
  4. Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13
Fluorescent lamp T8 - 26mm diameter, light colour 830, high luminous efficiency, good colour rendering, long life, base G13. Controllable by Dim-ECG.
  • Ajouter pour comparer
  • PDF
  • Calculate consumption data
  •  
  • 30.0 W
  • 2400 lm
  • 3000 K
  • 20000 h
  • Rod
  • Inactif

Galerie d'images

Produktbild - Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13
Produktbild - Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13
Zeichnung - Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13
Energielabel - Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13
Energielabel - Fluorescent lamp Spectralux®Plus , NL-T8 30W/830/G13
Picto

General Data

31518151
NL-T8 30W/830/G13
4008597181511
25
4008597481512
3.525
0.928
0.148
0.15
124 g
Inactif

Electric Parameters

30.0 W
36 kWh
96 V
220-240 V
365 mA
4.5 µF

Light Application Parameters

2400 lm
2400 lm
25 °C
360 °
80 lm/W
74 lm/W
warm white
830
3000 K
>=80
1.2
0.96
0.94
0.93
0.91
0.91

Service Life

20000 h
20000 h
0.99
0.99
0.99
0.99
0.90

Specification

old label, no EPREL registration, no EU data sheet
G
A
26 mm
26 mm
895 mm
895 mm
2.5 mg
Rod
G13
White

Notes on Operation

Non

Information especially for EPREL

old label, no EPREL registration, no EU data sheet
868653

Miscellaneous

25.08.2023
RoHS
31519991

Notices explicatives

Culot

Sockel-ZeichnungG13
IEC/EN 60061-1
sheet 7004-51-8

Courbes spectrales

Natural daylight is a mixture of direct sunlight and the light of the sky. Therefore, its spectral composition changes permanently due to the changing time of day. The standardised light classification D65 corresponds to a daylight with a colour temperature of approximately 6500 K.
Every fluorescent lamp type has got an individual spectral power distribution according to its phosphor coating inside the bulb. From this result important properties light colour or colour rendering.
Visible region from 380 to 780 nm; height of graph corresponding with relative spectral emission (400mW/klm) per 10nm.

Spektrum 1light colour 830 Spectralux® Warm white (31)

Spektrum 2daylight(D 65)

Exemple(s) de circuit

Schaltbild1One-lampe ciruit inductive
Key:
D = choke
L. = lamp
St = starter
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor

The required control gear (here starter and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2One-lampe ciruit with electronic ballast
Key:
VG = ballast electronic (ECG)
P = phase
N = zero potential
Ctrl = Controller, dimmer

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2One-lampe ciruit with electronic ballast
Key:
VG = ballast electronic (ECG)
P = phase
N = zero potential
Ctrl = Controller, dimmer

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2One-lampe ciruit with electronic ballast
Key:
VG = ballast electronic (ECG)
P = phase
N = zero potential
Ctrl = Controller, dimmer

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild3Circuit with multi electronic ballast
Key:
VG = ballast electronic (ECG)
P = phase
N = zero potential
Ctrl = Controller, dimmer

The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild4Serious connection with conventional (low loss) ballast
Key:
D = choke
L. = lamp
St = starter
VG = ballast electromagnetic (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor

The required control gear (here starter and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild5Three phase current connection
Key:
D = choke
L. = lamp
St = starter
VG = ballast electromagnetic (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor

The required control gear (here starter and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Particularités

Picto

Notices explicatives générales

The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages.
® = Registered trademark
Subject to change without notice. Errors and omissions excepted.


Téléchargements

Energylabel acc. to 2019/2015, A to G
Energylabel acc. to 874/2012, A++ to E
Declaration of Conformity
User Instruction

Produits assortis

Produits similaires

Consommation d'énergie

Puissance
30.0 W
Mean service life
20000 h
Number of lamps (pcs)
Number of burning hours (h)
Frais d'électricité (€ / kWh)
Consommation d'énergie
Coûts d'électricité
Transfer to LED‘s Save
calculer

Cable Length

Number of lamps (pcs)
Cable cross-section
Voltage drop
Max. cable length
calculer

Cable Length

Number of lamps (pcs)
Cable cross-section
Voltage drop
Max. cable length
calculer

Comparer les produits

Compare products or see the products that have been saved to comparison.

Plus

LED‘s Save

 LED´s Save

Echanger et économiser en utilisant des lampes LED Radium

Trouver votre lampe de remplacement LED et calculer vos économies.

calculer

Consommation d'énergie / coûts

Consommation d'énergie kWh par an
Coûts d'électricité par an
Lamp costs per year:
Total cost per year:
31518151
€

Additional basic data:

Usage Scenario:
Ménage
Compare with LED

Product News

le rayonnement VUV

La lumière perfectionne les surfaces de silicone.

23.02.2023 - Le rayonnement VUV le rend possible.

Le silicone est un matériau vraiment polyvalent: flexible, extensible et pourtant résistant à la température. En outre, il…

angle de rayonnement LED Spot GU10

Quel angle de rayonnement pour les spots LED GU10 ?

17.11.2022 - Des lampes LED professionnelles pour chaque application.

Le populaire spot halogène PAR16, qui pouvait tout simplement être utilisé sur une tension de 230V, laisse à son successeur…

En lire plus

Find a dealer

Search dealers in your area

Feedback

Footer

  • © Radium 2026
  • Conditions d'utilisation
  • CGV
  • Contact
  • Mentions légales
  • Politique Radium en matière de cookies
  • Protection des données personnelles